J Pharm Biomed Anal ; 215: 114755, 2022 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-35430411

RESUMO

Chemometrics applied to spectroscopic measurements such as near-infrared are gaining more and more importance for quality control of pharmaceutical products. Handheld near-infrared devices show great promise as a medicines quality screening technique for post-marketing surveillance. These devices are able to detect substandard and falsified medicines in pharmaceutical supply chains and enable rapid action before these medicines reach patients. The instrumental and environmental changes, expected or not, can adversely affect the analytical performances of prediction models developed for routine applications. Based on a previous study, PLS prediction models were developed and validated on three similar handheld NIR transmission spectrophotometers of the same model and from same company. These models have shown to be effective in analyzing metformin tablet samples, but significant spectral differences between handheld systems complicated their deployment for routine analysis. In this study, different strategies have been applied and compared to correct the instrumental variations, including global modelling (GM) and calibration transfer methods (Direct Standardization, DS; Spectral Space Transformation, SST and Slope/Bias correction, SBC), considering the RMSEP and the accuracy profile as assessment criteria. The transfer methods showed good capabilities to maintain the predictive performances comparable to that of the global modelling approach, except for a remaining slight bias. This approach is interesting since very few standardization samples are required to develop an adequate transfer model. GM, SST and SBC were able to correct/handle drifts in the spectral responses of different handheld instruments and thus may help to avoid the need for a long, laborious, and costly full recalibration process due to inter-instrument variations.


Assuntos
Medicamentos Falsificados , Espectroscopia de Luz Próxima ao Infravermelho , Calibragem , Medicamentos Falsificados/análise , Humanos , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Comprimidos/química
2.
J Pharm Biomed Anal ; 194: 113761, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33234414

RESUMO

The proliferation of falsified medicines can cause serious public health issues, particularly in the context of a global pandemic such as the actual COVID-19 pandemic. Our study involved eight chloroquine phosphate medicines seized in Cameroon, Democratic Republic of Congo and Niger during March and May 2020. These suspect samples were first analyzed in a screening phase using field tools such as handheld Raman spectroscopy (TruScan) and then in a confirmation phase using laboratory tools such as hyperspectral Raman imaging and High Performance Liquid Chromatography (HPLC). The results confirmed the falsified nature of the samples, highlighting the presence of metronidazole at low dose in four samples (16.6, 15.2, 15.2 and 14.5 mg/tab), too low levels of chloroquine in two samples (2.4 and 20.2 mg/tab), and substitution of chloroquine phosphate by paracetamol in one sample (255.7 mg/tab). The results also confirmed that four samples had been adulterated with paracetamol in trace amounts and two of them presented traces of chloramphenicol.


Assuntos
COVID-19/epidemiologia , Cloroquina/análogos & derivados , Medicamentos Falsificados/análise , Pandemias , Análise Espectral Raman/métodos , Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/uso terapêutico , Antimaláricos/análise , Antimaláricos/uso terapêutico , Cloroquina/análise , Cloroquina/uso terapêutico , Cromatografia Líquida de Alta Pressão/métodos , Medicamentos Falsificados/uso terapêutico , Humanos , Comprimidos , Tratamento Farmacológico da COVID-19
3.
Talanta ; 207: 120306, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31594606

RESUMO

Handheld Raman spectroscopy is actually booming. Recent devices improvements aim at addressing the usual Raman spectroscopy issues: fluorescence with shifted-excitation Raman difference spectroscopy (SERDS), poor sensitivity with surface enhanced Raman scattering (SERS) and information only about the sample surface with spatially offset Raman spectroscopy (SORS). While qualitative performances of handheld devices are generally well established, the quantitative analysis of pharmaceutical samples remains challenging. The aim of this study was to compare the quantitative performances of three commercially available handheld Raman spectroscopy devices. Two of them (TruScan and IDRaman mini) are equipped with a 785 nm laser wavelength and operate in a conventional backscattering mode. The IDRaman has the Orbital Raster Scanning (ORS) option to increase the analyzed surface. The third device (Resolve) operates with an 830 nm laser wavelength both in backscattering and in SORS modes. The comparative study was carried out on ibuprofen-mannitol-microcrystalline cellulose ternary mixtures. The concentration of ibuprofen ranged from 24 to 52% (w/w) while the proportions of the two excipients were varied to avoid cross-correlation as much as possible. Analyses were performed either directly through a glass vial or with the glass vial in an opaque polypropylene flask, using a validated FT-NIR spectroscopy method as a reference method. Chemometric analyses were carried out with the Partial Least Squares Regression (PLS-R) algorithm. The quantitative models were validated using the total error approach and the ICH Q2 (R1) guidelines with ±â€¯15% as acceptance limits.


Assuntos
Preparações Farmacêuticas/análise , Embalagem de Produtos , Espectrofotometria/instrumentação , Análise Espectral Raman/instrumentação , Vidro , Ibuprofeno/análise , Polipropilenos
4.
Talanta ; 202: 469-478, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31171209

RESUMO

Over the last decade, the growth of the global pharmaceutical market has led to an overall increase of substandard and falsified drugs especially on the African market (or emerging countries). Recently, several methods using handheld/portable vibrational spectroscopy have been developed for rapid and on-field drug analysis. The objective of this work was to evaluate the performances of various NIR and Raman handheld spectrophotometers in specific brand identification of medicines through their primary packaging. Three groups of drug samples (artemether-lumefantrine, paracetamol and ibuprofen) were used in tablet or capsule forms. In order to perform a critical comparison, the analytical performances of the two analytical systems were compared statistically using three methods: hierarchical clustering algorithm (HCA), data-driven soft independent modelling of class analogy (DD-SIMCA) and hit quality index (HQI). The overall results show good detection abilities for NIR systems compared to Raman systems based on Matthews's correlation coefficients, generally close to one. Raman systems are less sensitive to the physical state of the samples than the NIR systems, it also suffers of the auto-fluorescence phenomenon and the signal of highly dosed active pharmaceutical ingredient (e.g. paracetamol or lumefantrine) may mask the signal of low-dosed and weaker Raman active compounds (e.g. artemether). Hence, Raman systems are less effective for specific product identification purposes but are interesting in the context of falsification because they allow a visual interpretation of the spectral signature (presence or absence of API).


Assuntos
Medicamentos Falsificados/análise , Algoritmos , Raios Infravermelhos , Análise Espectral Raman
5.
J Chromatogr A ; 1515: 209-217, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28811100

RESUMO

Nowadays, many efforts are devoted to improve analytical methods regarding efficiency, analysis time and greenness. In this context, Supercritical Fluid Chromatography (SFC) is often regarded as a good alternative over Normal Phase Liquid Chromatography (NPLC). Indeed, modern SFC separations are fast, efficient with suitable quantitative performances. Moreover, the hyphenation of SFC to mass spectrometry (MS) provides additional gains in specificity and sensitivity. The present work aims at the determination of vitamin D3 by SFC-MS for routine Quality Control (QC) of medicines specifically. Based on the chromatographic parameters previously defined in SFC-UV by Design of Experiments (DoE) and Design Space methodology, the method was adapted to work under isopycnic conditions ensuring a baseline separation of the compounds. Afterwards, the response provided by the MS detector was optimized by means of DoE methodology associated to desirability functions. Using these optimal MS parameters, quantitative performances of the SFC-MS method were challenged by means of total error approach method validation. The resulting accuracy profile demonstrated the full validity of the SFC-MS method. It was indeed possible to meet the specification established by the European Medicines Agency (EMA) (i.e. 95.0 - 105.0% of the API content) for a dosing range corresponding to at least 70.0-130.0% of the API content. These results highlight the possibility to use SFC-MS for the QC of medicine and obviously support the switch to greener analytical methods.


Assuntos
Colecalciferol/análise , Cromatografia com Fluido Supercrítico/métodos , Espectrometria de Massas/métodos , Óleos/análise , Composição de Medicamentos , Controle de Qualidade , Sensibilidade e Especificidade
6.
Eur J Paediatr Dent ; 18(1): 19-22, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28494597

RESUMO

AIM: Impaction of deciduous teeth is an uncommon event. The purpose of this report is to describe two unusual eruption failures of a second primary molar and their treatment management. CASE REPORT: The diagnostic and therapeutic protocol of two cases selected at the Unit of Paediatric Dentistry, Department of Oral and Maxillofacial Science, "Sapienza" University of Rome, Italy, are presented. In both cases, the second deciduous molar was impacted, while no mechanical obstacle like odontomas or supernumerary teeth were present. CONCLUSION: The two case reports presented in this work are of scientific relevance, due to the rarity of this type of pathology.


Assuntos
Extração Dentária , Dente Impactado/cirurgia , Criança , Feminino , Humanos , Masculino , Ortodontia Corretiva , Radiografia Panorâmica , Tomografia Computadorizada por Raios X , Dente Decíduo , Dente Impactado/diagnóstico por imagem
7.
Lupus ; 26(5): 478-483, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28394234

RESUMO

Objective To investigate serologic S100ß protein levels in childhood-onset SLE patients (cSLE) and to elucidate their association with disease activity and neuropsychiatric (NP) manifestations. Methods We included 71 cSLE patients (67 females; median age 18 years; range 9-37 and 53 (47 females; median age of 20 years; range 6-29) age and sex matched healthy controls. Neurological manifestations were analysed according to the American College of Rheumatology (ACR) criteria. Cognitive evaluation was performed in all participants using Wechsler Intelligence Scale for Children (WISC-III) and Wechsler Adult Intelligence Scale (WAIS), according to age, and validated in Portuguese. SLE patients were further assessed for clinical and laboratory SLE manifestations, disease activity (SLE Disease Activity Index (SLEDAI)), damage (Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SDI)) and current drug exposures. Sera S100ß protein levels were measured by enzyme-linked immunosorbent assay using commercial kits. Results The median S100ß protein level was 116.55 pg/mL (range 1.53-468.50) in cSLE and 54.98 pg/mL (range 0.69-181.00) in healthy controls ( p < 0.001). An association was observed between S100ß protein and NP manifestations ( p = 0.03). The S100ß protein levels was associated with cognitive impairment in cSLE patients ( p = 0.006). Conclusions S100ß protein levels are increased in cSLE with cognitive impairment. S100ß may be considered a potential biomarker that underlies central nervous system (CNS) dysfunction, especially cognitive impairment.


Assuntos
Disfunção Cognitiva/metabolismo , Lúpus Eritematoso Sistêmico/psicologia , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Adolescente , Adulto , Idade de Início , Criança , Disfunção Cognitiva/etiologia , Feminino , Humanos , Lúpus Eritematoso Sistêmico/metabolismo , Masculino , Regulação para Cima , Adulto Jovem
8.
J Chromatogr A ; 1491: 171-181, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28242051

RESUMO

In the uprising context of green analytical chemistry, Supercritical Fluid Chromatography (SFC) is often suggested as an alternative to Normal Phase Liquid Chromatography. Indeed, SFC provides fast, efficient and green separations. In this report, the quantitative performances of SFC were challenged on a real-life case study: the Quality Control (QC) of vitamin D3. A rapid and green SFC method was optimized thanks to the Design of Experiments-Design Space (DoE-DS) methodology. It provided robust and high quality separation of the compounds within a 2min timeframe, using a gradient of ethanol as co-solvent of the carbon dioxide. The analytical method was fully validated according to the total error approach, demonstrating the compliance of the method to the specifications of U.S. Pharmacopeia (USP: 97.0-103.0%) and European Pharmacopeia (EP: 97.0-102.0%) for an interval of [50-150%] of the target concentration. In order to allow quantification of impurities using vitamin D3 as an external standard in SFC-UV, correction factors were determined and verified during method validation. Thus, accurate quantification of impurities was demonstrated at the specified levels (0.1 and 1.0% of the main compound) for a 70.0-130.0% dosing range. This work demonstrates the validity of an SFC method for the QC of vitamin D3 raw material and its application to real samples. Therefore, it supports the switch to a greener and faster separative technique as an alternative to NPLC in the pharmaceutical industry.


Assuntos
Colecalciferol/análise , Cromatografia com Fluido Supercrítico/métodos , Colecalciferol/química , Colecalciferol/normas , Contaminação de Medicamentos , Reprodutibilidade dos Testes
9.
Lupus ; 26(4): 417-425, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27872396

RESUMO

Objective We aimed to compare estimates of body fat content with respect to their ability to predict the percentage of body fat, confirmed by dual-energy X-ray absorptiometry scans in childhood-onset systemic lupus erythematosus. Methods We included 64 consecutive childhood-onset systemic lupus erythematosus patients and 64 healthy age and sex-matched controls in a cross-sectional study. Anthropometric data, body mass index and body adiposity index were calculated for all subjects. Childhood-onset systemic lupus erythematosus patients were further assessed for clinical and laboratory childhood-onset systemic lupus erythematosus manifestations and fat mass, lean mass and percentage of body fat evaluated by dual-energy X-ray absorptiometry. Results Elevated waist/hip ratio was observed in childhood-onset systemic lupus erythematosus patients when compared to controls ( p < 0.001). We did not find differences between body mass index and body adiposity index classification in childhood-onset systemic lupus erythematosus patients and controls. Using dual-energy X-ray absorptiometry as gold standard we observed that all indirect estimates of body fat were correlated with whole body fat mass. We observed a correlation between height and cumulative corticosteroid dose adjusted by weight ( r = 0.429, p = 0.005) in childhood-onset systemic lupus erythematosus. On whole body analysis we observed a correlation between lean mass and ACR Damage Index scores ( r = -0.395; p = 0.019); percentage of body fat and adjusted Systemic Lupus Erythematosus Disease Activity Index ( r = 0.402; p = 0.008), disease duration ( r = -0.370; p = 0.012). On trunk analysis we observed a correlation between lean mass and ACR Damage Index ( r = -0.319; p = 0.042); percentage of body fat with adjusted Systemic Lupus Erythematosus Disease Activity Index ( r = 0.402; p = 0.005), disease duration ( r = -0.408; p = 0.005). Conclusions This is the first study analyzing body adiposity index in childhood-onset systemic lupus erythematosus patients. We observed that all indirect estimates of body fat were correlated with whole body fat mass. This study shows that we should not replace body mass index by body adiposity index to evaluating fat levels in childhood-onset systemic lupus erythematosus. In consideration of the importance of overweight classification in cardiovascular diseases, any direct estimates of body fat can be used in an attempt to improve the prognosis of patients. Note We believe that we have presented evidence of body adiposity index accuracy in childhood-onset systemic lupus erythematosus patients but further research on the generalizability of body adiposity index to other patient groups needs to be done.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Absorciometria de Fóton/métodos , Adolescente , Corticosteroides/uso terapêutico , Idade de Início , Índice de Massa Corporal , Estudos de Casos e Controles , Criança , Estudos Transversais , Feminino , Humanos , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Masculino , Adulto Jovem
10.
Med. Afr. noire (En ligne) ; 64(03): 135-144, 2017. ilus
Artigo em Francês | AIM (África) | ID: biblio-1266233

RESUMO

Introduction : La quinine est une molécule préconisée pour le traitement du paludisme dans les régions où les souches de P. falciparum sont poly-résistantes. Face à l'importante utilisation de ses médicaments génériques d'une part, et au fléau des médicaments de qualité inférieure d'autre part, il devient plus que nécessaire d'appuyer les données des tests physico-chimiques par celles de dissolution in vitro dont l'évaluation et la comparaison des cinétiques permettra de prédire le comportement in vivo du principe actif et par conséquent l'efficacité du médicament générique. L'objectif de la présente étude était de réaliser une étude comparative de la cinétique de dissolution d'un princeps et d'un générique à base de quinine comprimé 300 mg commercialisés à Kinshasa.Matériels et méthodes : L'étude a été réalisée en utilisant trois milieux de pH différents (1,2 - 4,5 - 6,8) tels que recommandés par l'Agence Européenne de Médicament et en se servant d'un appareil de dissolution, tandis que l'équipement de chromatographie liquide à haute performance couplée à un détecteur à barrette de diodes a été utilisé pour la quantification. La méthode statistique fit factor a été appliquée pour comparer les résultats de dosage de la quinine dans les trois milieux tout en ayant évalué le biais à différents temps de dissolution.Résultats : Les différents échantillons de médicaments générique et princeps ont été conformes quant à l'identification et au dosage de la quinine, par contre leurs cinétiques de dissolution étaient non-similaires.Discussion : Ceci pourrait avoir une influence sur l'efficacité du produit générique et la sécurité des consommateurs, dénotant l'importance d'examiner les profils de dissolution des génériques avant toute autorisation de mise sur le marché plus particulièrement dans les pays en voie de développement


Assuntos
Cromatografia Líquida de Alta Pressão , Estudo Comparativo , República Democrática do Congo , Liberação Controlada de Fármacos , Substituição de Medicamentos , Quinina
11.
J Pharm Biomed Anal ; 128: 382-390, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27343901

RESUMO

African populations use traditional medicines in their initial attempt to treat a range of diseases. Nevertheless, accurate knowledge of the composition of these drugs remains a challenge in terms of ensuring the health of population and in order to advance towards improved traditional medicines (ITMs). In this paper chromatographic methods were developed for qualitative and quantitative analyses of a per os antimalarial ITM containing Garcinia kola. The identified analytical markers were used to establish TLC and HPLC fingerprints. G. kola seeds were analysed by HPLC to confirm the identity of the extract used by the Congolese manufacturer in the ITM. The main compounds (GB1, GB2, GB-1a and Kolaflavanone) were isolated by preparative TLC and identified by UPLC-MS and NMR. For the quantification of the major compound GB1, a simple and rapid experimental design was applied to develop an LC method, and then its validation was demonstrated using the total error strategy with the accuracy profile as a decision tool. The accurate results were observed within 0.14-0.45mg/mL range of GB1 expressed as naringenin. The extracts used in several batches of the analysed oral solutions contained GB1 (expressed as naringenin) within 2.04-2.43%. Both the fingerprints and the validated LC-DAD were found suitable for the quality control of G. kola-based raw material and finished products, respectively.


Assuntos
Antimaláricos/análise , Biflavonoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Garcinia kola/química , Extratos Vegetais/química , Antimaláricos/isolamento & purificação , Biflavonoides/isolamento & purificação , Flavanonas/análise , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Sementes/química
12.
Vet Pathol ; 53(2): 349-65, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26936751

RESUMO

Ferrets have become more popular as household pets and as animal models in biomedical research in the past 2 decades. The average life span of ferrets is about 5-11 years with onset of geriatric diseases between 3-4 years including endocrinopathies, neoplasia, gastrointestinal diseases, cardiomyopathy, splenomegaly, renal diseases, dental diseases, and cataract. Endocrinopathies are the most common noninfectious disease affecting middle-aged and older ferrets. Spontaneous neoplasms affecting the endocrine system of ferrets appear to be increasing in prevalence with a preponderance toward proliferative lesions in the adrenal cortex and pancreatic islet cells. Diet, gonadectomy, and genetics may predispose ferrets to an increased incidence of these endocrinopathies. These functional proliferative lesions cause hypersecretion of hormones that alter the physiology and metabolism of the affected ferrets resulting in a wide range of clinical manifestations. However, there is an apparent dearth of information available in the literature about the causal relationship between aging and neoplasia in ferrets. This review provides a comprehensive overview of the anatomy and physiology of endocrine organs, disease incidence, age at diagnosis, clinical signs, pathology, and molecular markers available for diagnosis of various endocrine disorders in ferrets.


Assuntos
Envelhecimento/patologia , Doenças do Sistema Endócrino/veterinária , Furões , Idade de Início , Envelhecimento/genética , Animais , Sistema Endócrino/patologia , Sistema Endócrino/fisiologia , Doenças do Sistema Endócrino/diagnóstico , Doenças do Sistema Endócrino/genética , Doenças do Sistema Endócrino/patologia , Modelos Animais , Animais de Estimação
13.
Lupus ; 25(7): 754-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26821966

RESUMO

OBJECTIVE: The aim of this multicenter study in a large childhood-onset systemic lupus erythematosus (cSLE) population was to assess the herpes zoster infection (HZI) prevalence, demographic data, clinical manifestations, laboratory findings, treatment, and outcome. METHODS: A retrospective multicenter cohort study (Brazilian cSLE group) was performed in ten Pediatric Rheumatology services in São Paulo State, Brazil, and included 852 cSLE patients. HZI was defined according to the presence of acute vesicular-bullous lesions on erythematous/edematous base, in a dermatomal distribution. Post-herpetic neuralgia was defined as persistent pain after one month of resolution of lesions in the same dermatome. Patients were divided in two groups for the assessment of current lupus manifestations, laboratory findings, and treatment: patients with HZI (evaluated at the first HZI) and patients without HZI (evaluated at the last visit). RESULTS: The frequency of HZI in cSLE patients was 120/852 (14%). Hospitalization occurred in 73 (61%) and overlap bacterial infection in 16 (13%). Intravenous or oral aciclovir was administered in 113/120 (94%) cSLE patients at HZI diagnosis. None of them had ophthalmic complication or death. Post-herpetic neuralgia occurred in 6/120 (5%). After Holm-Bonferroni correction for multiple comparisons, disease duration (1.58 vs 4.41 years, p < 0.0001) was significantly lower in HZI cSLE patients compared to those without HZI. Nephritis (37% vs 18%, p < 0.0001), lymphopenia (32% vs 17%, p < 0.0001) prednisone (97% vs 77%, p < 0.0001), cyclophosphamide (20% vs 5%, p < 0.0001) and SLE Disease Activity Index 2000 (6.0 (0-35) vs 2 (0-45), p < 0.0001) were significantly higher in the former group. The logistic regression model showed that four independent variables were associated with HZI: disease duration < 1 year (OR 2.893 (CI 1.821-4.597), p < 0.0001), lymphopenia <1500/mm(3) (OR 1.931 (CI 1.183-3.153), p = 0.009), prednisone (OR 6.723 (CI 2.072-21.815), p = 0.002), and cyclophosphamide use (OR 4.060 (CI 2.174-7.583), p < 0.0001). CONCLUSION: HZI is an early viral infection in cSLE with a typical dermatomal distribution. Lymphopenia and immunosuppressive treatment seem to be major factors underlying this complication in spite of a benign course.


Assuntos
Ciclofosfamida/efeitos adversos , Herpes Zoster/epidemiologia , Imunossupressores/efeitos adversos , Lúpus Eritematoso Sistêmico/complicações , Prednisona/efeitos adversos , Aciclovir/administração & dosagem , Adolescente , Adulto , Idade de Início , Antivirais/administração & dosagem , Brasil/epidemiologia , Criança , Pré-Escolar , Feminino , Herpes Zoster/tratamento farmacológico , Hospitalização/estatística & dados numéricos , Humanos , Lactente , Modelos Logísticos , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Linfopenia/epidemiologia , Masculino , Nefrite/epidemiologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
14.
J Pharm Biomed Anal ; 111: 21-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25828509

RESUMO

Poor quality antimalarial drugs are one of the public's major health problems in Africa. The depth of this problem may be explained in part by the lack of effective enforcement and the lack of efficient local drug analysis laboratories. To tackle part of this issue, two spectroscopic methods with the ability to detect and to quantify quinine dihydrochloride in children's oral drops formulations were developed and validated. Raman and near infrared (NIR) spectroscopy were selected for the drug analysis due to their low cost, non-destructive and rapid characteristics. Both of the methods developed were successfully validated using the total error approach in the range of 50-150% of the target concentration (20%W/V) within the 10% acceptance limits. Samples collected on the Congolese pharmaceutical market were analyzed by both techniques to detect potentially substandard drugs. After a comparison of the analytical performance of both methods, it has been decided to implement the method based on NIR spectroscopy to perform the routine analysis of quinine oral drop samples in the Quality Control Laboratory of Drugs at the University of Kinshasa (DRC).


Assuntos
Antimaláricos/química , Bioensaio/métodos , Soluções Farmacêuticas/análise , Soluções Farmacêuticas/química , Quinina/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise Espectral Raman/métodos , Administração Oral , África , Controle de Qualidade
15.
Case Rep Dent ; 2015: 976756, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26788379

RESUMO

Purpose. Implant therapy plays an important role in contemporary dentistry with high rates of long-term success. However, in recent years, the incidence of peri-implantitis and implant failures has significantly increased. The peripheral giant cell granuloma (PGCG) rarely occurs in peri-implant tissues and it is clinically comparable to the lesions associated with natural teeth. Therefore, the study of possible diseases associated with dental implants plays an important role in order to be able to diagnose and treat these conditions. Materials and Methods. This report described a 60-year-old Caucasian male who presented a reddish-purple pedunculated mass, of about 2 cm in diameter, associated with a dental implant and the adjacent natural tooth. Results. An excisional biopsy was performed and the dental implant was not removed. Histological examination provided the diagnosis of PGCG. After 19-month follow-up, there were no signs of recurrence of peri-implantitis around the implant. Conclusion. The correct diagnosis and appropriate surgical treatment of peri-implant giant cell granuloma are very important for a proper management of the lesion in order to preserve the implant prosthetic rehabilitation and prevent recurrences.

16.
West Indian med. j ; 62(8): 701-704, Nov. 2013.
Artigo em Inglês | LILACS | ID: biblio-1045736

RESUMO

PURPOSE: Clonality detection through amplifying immunoglobulin heavy chain (IGH) gene rearrangements by polymerase chain reaction (PCR) is a useful tool in diagnosis of various B-lymphoid malignancies. Immunoglobulin heavy chain gene rearrangement can be an optimal target for clonality detection in B-lymphoid malignancies. In the present study, we evaluated the presence of IGH gene rearrangement in non B-cell haemato-oncologypatients including T-cell acute lymphoblastic leukaemia (T-ALL), acute myeloblastic leukaemia (AML) and biphenotypic leukaemia. METHODS: We studied 18 cases of haematological malignancies which comprised five patients with TALL, 12 patients with AML and one with biphenotypic leukaemia. RESULTS: We found that the incidence of IGH gene rearrangement in T-ALL and AML were three (60%) and two (16.7%), respectively. The patient with biphenotypic leukaemia was negative for IGH gene rearrangement. CONCLUSION: Immunoglobulin gene rearrangement, which occurs in almost all haematological malignancies of B-cell lineage, also presents in a very small proportion of T-cell or myeloid malignancies.


OBJETIVO: La detección de la clonalidad mediante amplificación de los reordenamientos del gen de la cadena pesada (IGH) de inmunoglobulina por reacción en cadena de la polimerasa (RCP) es una herramienta útil en el diagnóstico de varios tumores malignos linfoides de células B. El reordenamiento del gen de la cadena pesada de inmunoglobulina puede ser un objetivo óptimo de la detección de la clonalidad en tumores malignos linfoides de células B. En el presente estudio, se evaluó la presencia de reordenamiento del gen IGH en pacientes de hemato-oncología de células no B, incluyendo la leucemia linfoblástica aguda de células T (LLA-T), leucemia mieloblástica aguda (LMA), y leucemia bifenotípica. MÉTODOS: Se estudiaron 18 casos de neoplasias malignas hematológicas que abarcaron cinco pacientes con (LLA-T), 12pacientes con AML y uno con leucemia bifenotípica. CONCLUSIÓN: Reordenamiento del gen de la inmunoglobulina que ocurre en casi todas las neoplasias malignas hematológicas del linaje de las células B, también se presenta en una proporción muy pequeña de células T o las neoplasias mieloides.


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Rearranjo Gênico/genética , Leucemia Aguda Bifenotípica/genética , Leucemia Mieloide Aguda/genética , Genes de Cadeia Pesada de Imunoglobulina/genética , Leucemia-Linfoma Linfoblástico de Células T Precursoras/genética , Reação em Cadeia da Polimerase , Estudos Prospectivos
17.
Am J Med Genet A ; 161A(11): 2697-703, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24166811

RESUMO

INTRODUCTION: The following paper by Professor GiovanniNeri and colleagues was originally published in 1988, American Journal of Medical Genetics 30:287­299. This paper represented a seminal work at the time of publication as it not only reported a new family with a disorder that had been called the "gigantism-dysplasia syndrome", but also suggested naming the condition the Simpson-Golabi-Behmel syndrome. This eponym has clearly stood "the test of time", and that designation is now widely accepted. This paper is graciously republished by Wiley-Blackwell in the Special Festschrift issue honoring Professor Neri. We report on another family with the so-called "gigantism-dysplasia syndrome", an X-linked condition characterized by pre-and postnatal overgrowth, characteristic face with apparent coarseness, dysplastic changes in several tissues, and mild intellectual impairment. This condition has been called the Golabi-Rosen syndrome; however, we agree that is the same entity as that described, in a milder form, by Simpson et al. in 1975 and by Behmel et al. in 1984. Therefore, we suggest that this entity be designated the Simpson-Golabi-Behmel syndrome. The manifestations in affected individuals suggest that this condition represents an X-linked encephalo-tropho-schisis syndrome.


Assuntos
Arritmias Cardíacas/história , Doenças Genéticas Ligadas ao Cromossomo X/história , Gigantismo/história , Cardiopatias Congênitas/história , Deficiência Intelectual/história , Arritmias Cardíacas/diagnóstico , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico , Gigantismo/diagnóstico , Cardiopatias Congênitas/diagnóstico , História do Século XXI , Humanos , Deficiência Intelectual/diagnóstico , Masculino
18.
J Pharm Biomed Anal ; 85: 83-92, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23912056

RESUMO

The poor quality of medicines is a crucial problem of public health. Therefore, it is important to have analytical tools to attend decisions of the legal authorities while combating this offense. In this context, the main objective of this study was to develop generic methods able to trace, screen and determine several antibiotics and common associated molecules by mean of liquid chromatographic techniques. For that purpose, an innovative Design Space optimization strategy was applied, targeting 16 antibiotics and 3 beta-lactamase inhibitors. The robustness of the developed method allowed using its use in an environment where operational factors such as temperature are not easy to control and eased its transfer to Ultra High Performance Liquid Chromatography. To demonstrate its ability to quantify the targeted molecules, the developed and transferred method was fully validated for two active ingredients commonly used in association, sulbactam and ceftriaxone, using the accuracy profile as decision tool. Based on this successful step, the method was then used for the quantitative determination of these two active ingredients in three pharmaceutical brands marketed in the Democratic Republic of Congo. Two out of the three pharmaceutical products did not comply with the specifications.


Assuntos
Antibacterianos/análise , Cromatografia Líquida de Alta Pressão/métodos , Antibacterianos/normas
19.
Anal Chem ; 85(13): 6327-35, 2013 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-23777474

RESUMO

The reliability of analytical results obtained with quantitative analytical methods is highly dependent on the selection of the adequate model used as the calibration curve. To select the adequate response function or model the most used and known parameter is to determine the coefficient R(2). However, it is well-known that it suffers many inconveniences, such as leading to overfitting the data. A proposed solution is to use the adjusted determination coefficient R(adj)(2) that aims at reducing this problem. However, there is another family of criteria that exists to allow the selection of an adequate model: the information criteria AIC, AICc, and BIC. These criteria have rarely been used in analytical chemistry to select the adequate calibration curve. This works aims at assessing the performance of the statistical information criteria as well as R(2) and R(adj)(2) for the selection of an adequate calibration curve. They are applied to several analytical methods covering liquid chromatographic methods, as well as electrophoretic ones involved in the analysis of active substances in biological fluids or aimed at quantifying impurities in drug substances. In addition, Monte Carlo simulations are performed to assess the efficacy of these statistical criteria to select the adequate calibration curve.


Assuntos
Sistemas de Informação , Método de Monte Carlo , Animais , Calibragem , Cromatografia Líquida/métodos , Humanos , Suínos
20.
West Indian Med J ; 62(8): 701-4, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25014854

RESUMO

OBJECTIVE: Clonality detection through amplifying immunoglobulin heavy chain (IGH) gene rearrangements by polymerase chain reaction (PCR) is a useful tool in diagnosis of various B-lymphoid malignancies. Immunoglobulin heavy chain gene rearrangement can be an optimal target for clonality detection in B-lymphoid malignancies. In the present study, we evaluated the presence of IGH gene rearrangement in non B-cell haemato-oncology patients including T-cell acute lymphoblastic leukaemia (T-ALL), acute myeloblastic leukaemia (AML) and biphenotypic leukaemia. MEHTODS: We studied 18 cases of haematological malignancies which comprised five patients with T-ALL, 12 patients with AML and one with biphenotypic leukaemia. RESULTS: We found that the incidence of IGH gene rearrangement in T-ALL and AML were three (60%) and two (16.7%), respectively. The patient with biphenotypic leukaemia was negative for IGH gene rearrangement. CONCLUSION: Immunoglobulin gene rearrangement, which occurs in almost all haematological malignancies of B-cell lineage, also presents in a very small proportion of T-cell or myeloid malignancies.

SELEÇÃO DE REFERÊNCIAS